JACOB throttle valves without inner flap seal precisely control air flow and product transport and, thanks to their
Show details
JACOB throttle valves without inner flap seal precisely control air flow and product transport and, thanks to their lipped ends, can be flexibly incorporated into the JACOB pull-ring system. Available in DN 60–400, powder-coated, galvanised or stainless steel. Both shaft feedthroughs are double-sealed (Viton O-ring plus conductive EPDM) and do not come into contact with the product; electrostatic charges are safely discharged to the housing. The stainless steel version is also available as FOOD GRADE, dually compliant with EC 1935/2004 and FDA. From DN 350 optionally with loose flanges.
For electric automation, the brushless JACOB E-Drive rotary actuator is used: 24 V AC/DC or 230 V AC, torque 20–400 Nm, switch-over times 1–5 s up to 110 Nm and 25 s at 200–400 Nm. Actuator flange to ISO 5211 (F03–F10) with output squares SW14/SW17/SW20, duty cycle 70 % (S3), setting range 0°–330°, protection class IP67, ambient temperature −20 to +60 °C. Both end positions and a third intermediate position are easily set via a 1.3″ OLED display. Electrical overload protection, integrated vibration protection, visual position indicator and emergency hand operation ensure high operational reliability.